ECOSCAN 10 - complex of digital radiography

ECOSCAN 10ECOSCAN 10
ECOSCAN 10, static portable flat panel X-ray detector ECOSCAN 10ECOSCAN 10, static portable flat panel X-ray detector ECOSCAN 10
static portable flat panel X-ray detector ECOSCAN 10
ECOSCAN 10, static portable flat-panel X-ray detector ECOSCAN 10 in a protective caseECOSCAN 10, static portable flat-panel X-ray detector ECOSCAN 10 in a protective case
static portable flat-panel X-ray detector ECOSCAN 10 in a protective case
ECOSCAN 10, static portable flat-panel X-ray detector ECOSCAN 10 in a protective caseECOSCAN 10, static portable flat-panel X-ray detector ECOSCAN 10 in a protective case
static portable flat-panel X-ray detector ECOSCAN 10 in a protective case
ECOSCAN 10, control panel on X-ray detector ECOSCAN 10ECOSCAN 10, control panel on X-ray detector ECOSCAN 10
control panel on X-ray detector ECOSCAN 10
ECOSCAN 10ECOSCAN 10
ECOSCAN 10, granular structure GadoxECOSCAN 10, granular structure Gadox
granular structure Gadox
ООО "Арион"
Price level: Retail
Retailcheckout at the office;
Online Starter*entry level benefits;
Online 1..5*five steps:
more orders - more benefits;
Online Wholesale*maximum benefit;
Online VIP*individual discount.

* valid only for orders placed on the site, according to the standard templates of contracts and accounts, it is mandatory to accept the Confidentiality Conditions for the information of an individual offer

155 354 Br
delivery time to 5 days
Buy

Ecoscan 10 wireless digital radiography complex is designed for non-destructive testing of industrial products by direct digital radiography. The use of the Ecoscan 10 complex eliminates the use of x-ray film and the need to maintain equipment and facilities for its chemical processing, interpretation and subsequent storage. The complex can be used in the control of hard-to-reach objects in the field and in the factory without the use of additional power sources.

The principle of operation of the Ecoscan 10 complex is based on the registration of X-ray radiation passing through the object of control and falling on the matrix of a flat-panel detector with its further conversion into a digital signal and obtaining an image on a personal computer screen that is available for further processing, analysis and storage.

The detector's scintillator converts the X-rays into visible light, which is received by the photodiode array. The analog electrical signal from each element of the photodiode array is converted by an analog-to-digital converter (ADC) into a digital format. The higher the bit depth of the ADC, the more shades of gray you can get. Further, the digital image is transmitted via wired or Wi-Fi connection to the operator's computer. Specialized software "Strazhnik" allows to carry out operational control of the complex and decipher the received image of the monitored object.

The detector's scintillator is made of gadolinium oxysulfide Gadox. Gadox has a granular structure and can be used in conditions of unavoidable direct exposure of X-rays to the working area of ​​the detector, bypassing the test object.

Benefits of Using Direct Digital Radiography
  • no need to use consumables and equipment for film development significantly reduces the cost of radiographic control;
  • short payback period of the complex even with small amounts of control;
  • archiving the received images in digital format;
  • high speed of obtaining the result compared to other methods of radiographic control, the flaw detector operator can start analyzing the image immediately after the end of the exposure;
  • wide functionality and choice of software tools speeds up the processing of the resulting image and ensures reliable detection of defects;
  • the option of tracking the location of equipment by GPS allows you to fix the coordinates of the place of control and automatically save them in the image parameters without the possibility of editing;
  • A flat-panel detector is much more sensitive to X-rays than an X-ray film, which can significantly save the life of the X-ray machine by reducing the required exposure time.
Features of Ecoscan 10 digital radiography complex
  • a wide range of detectors with different sizes of the effective working area and dimensions, created on the basis of various technologies of matrices and scintillators, allows solving a wide range of problems in the field of industrial non-destructive testing;
  • high sensitivity of the detector and wide dynamic range make it possible to control the product even if the object is in operation (presence of the product inside the pipelines, the outer layer of insulation, etc.);
  • the detector is powered both from AC mains and from replaceable batteries;
  • an additional set of batteries as part of the complex allows you to increase the battery life and perform control without the need to stop for recharging the batteries;
  • the components of the complex are protected from the influence of external factors, such as direct ingress of moisture and dust, and have high mechanical strength during physical impact during installation and transportation of equipment;
  • a special protective cover dampens possible shocks when the detecting unit is placed on the test object;
  • the X-ray sensor built into the detecting unit allows you to take pictures automatically after the start of the exposure;
  • the internal memory of the detector allows you to accumulate and combine the obtained images for further processing, without requiring communication with the control station of the flaw detection operator;
  • The flat-panel detector is adapted to work with both constant-potential X-ray machines and pulsed X-ray machines.
Features of the software "Strazhnik"
  • automatic determination of the basic spatial resolution by duplex wire standard;
  • building a profile showing the levels of change in grayscale to analyze the quality and uniformity of the image;
  • building a histogram showing the distribution of pixels in grayscale to optimize the contrast of individual areas of the image;
  • combining the frames accumulated during the exposure to form an image of better quality;
  • automatic measurement of the normalized signal-to-noise ratio;
  • changing the gain level of the signal received by the detector - used to avoid oversaturation of the gray level in the image if it is not possible to change the exposure mode of the X-ray machine;
  • calibration of the detector by offset, gain and dead pixels helps to improve the quality of the resulting image depending on the exposure mode;
  • image processing to improve the convenience of image decoding - changing the brightness, contrast, gamma correction either manually or using a set of ready-made filters (minimum and maximum alignment, sharpening, relief);
  • linear measurements on a scale set by the operator, determination and measurement of thinning or thickening of the material;
  • archival storage of data in the protected DICONDE format with subsequent creation of files in other formats (BMP, JPEG, TIFF).
  • DICONDE format images modified on third-party devices are marked with a special symbol that protects images from unwanted editing;
  • an intuitive interface will not cause difficulties in deciphering and processing images, even for beginners;
  • the ability to import external regulatory databases for working with defects and the formation of reports filled out based on image processing according to a pre-created template.
The composition of the complex

Ecoscan 10 digital radiography complex includes:

  • static portable flat panel x-ray detector,
  • protective case,
  • control station of the flaw detector operator with pre-installed software "Strazhnik",
  • a wireless access point that serves as an intermediate link between the control station and the detector in the absence of the possibility of establishing a direct wireless connection.

Thanks to the use of an industrial tablet computer, as well as an autonomous power supply system for the detector based on two sets of replaceable batteries, the complex is completely portable. The components of the complex are protected from the influence of external factors, such as direct ingress of moisture and dust, and have high mechanical strength during physical impact during installation and transportation of equipment. For additional protection of the detector, a protective cover is used, which dampens possible shocks when the detecting unit is placed on the test object.

The protective cover has the ability to position on the object of control using straps that can either cover the object or stretch on special magnetic fasteners.

Package includes
  • flat panel detector;
  • system control unit (Wi-Fi/Ethernet);
  • a set of additional detector batteries (2 pcs.);
  • detector battery charger
  • rugged tablet with pre-installed software "Strazhnik";
  • tablet case with stylus;
  • laptop with pre-installed software "Guardian";
  • transport case;
  • housing PPD with a device for fastening to the object of control;
  • power cable from the mains 220 V - 2 pcs.;
  • heating element for operation at low temperatures with a power supply;
  • passport and instruction manual;
  • Software "Strazhnik" *;
  • stand-alone power supply unit ELITEST ECO-24*;
  • two-wire standard Duplex IQI-D13 Kowotest (ISO 19232-5, ASTM E 2002)*;
  • magnetic wheels ECO-10MK*;
  • belt fastening ECO-10RK*;
  • magnetic holders ECO-10MD*.

* - advanced kit (until the end of 2022 included in the basic kit).

Technical Data
Measurement parameters
Range of registered energy of gamma radiation, keVfrom 40 to 300
Optical system
Photodiode Array Technologya-Si TFT
Scintillator typeGadox
Pixel Pitch, µm124
Number of pixels1 024 x 2 560
Control parameters
Effective zone size, mm127,0 x 317,0
Minimum distance from the matrix to the outer boundaries of the detector along the long side, mm6,0
Minimum distance from the matrix to the outer boundaries of the detector on the short side, mm9,0
Transducer
Bit depth of analog-to-digital converters, bit16
Environmental protection
International protection markingIP67
Dimensions and weight
Weight, kg3,200
Body (Height x Width x Length), mm25,0 x 160 x 400
Operating conditions
Operating temperature range, °Cfrom -40 to +40
Reviews

There are no reviews for this product yet.. Write the first review.

Отзыв

Overall score:
код

Thanks for your feedback!
The review will be published
after verification by the administrator

Close

Find out about the arrival

Close

Хотите скидку?

Хотите скидку?

Сначала войдите или зарегистрируйтесь!

Sign Up